The
aegis -Review_Begin_Undo
command is used to
stop reviewing a change.
It is moved from the being reviewed state back to the awaiting
review state.

If the review_begin_undo_notify_command has been set in the project
attributes, this command will be run. This is usually used to tell
other reviewers that you have stopped reviewing,
and they may like to do so instead.
See aepattr(5) and aepa(1) for more information.
If used when the develop_end_action project attribute is set to
goto_being_reviewed, then only the notification message is sent.
The following options are understood:
-Change numberThis option may be used to specify a particular change within a project. See aegis(1) for a complete description of this option.
-HelpThis option may be used to obtain more information about how to use the aegis program.
-ListThis option may be used to obtain a list of suitable subjects for this command. The list may be more general than expected.
-Project nameThis option may be used to select the project of interest.
When no
-Project
option is specified,
the
AEGIS_PROJECT
environment variable is consulted.
If that does not exist,
the user's
$HOME/.aegisrc
file is examined for a default project field (see
aeuconf(5)
for more information).
If that does not exist,
when the user is only working on changes within a single project,
the project name defaults to that project.
Otherwise,
it is an error.
-REAson textThis option may be used to attach a comment to the change history generated by this command. You will need to use quotes to insulate the spaces from the shell.
-TERseThis option may be used to cause listings to produce the bare minimum of information. It is usually useful for shell scripts.
-VerboseThis option may be used to cause aegis to produce more output.
By default aegis only produces output on errors.
When used with the
-List
option
this option causes column headings to be added.
-WaitThis option may be used to require Aegis commands to wait for access
locks, if they cannot be obtained immediately.
Defaults to the user's
lock_wait_preference
if not specified, see
aeuconf(5)
for more information.
-No_WaitThis option may be used to require Aegis commands to emit a fatal error
if access locks cannot be obtained immediately.
Defaults to the user's
lock_wait_preference
if not specified, see
aeuconf(5)
for more information.
See also aegis(1) for options common to all aegis commands.
All options may be abbreviated; the abbreviation is documented as the upper case letters, all lower case letters and underscores (_) are optional. You must use consecutive sequences of optional letters.
All options are case insensitive, you may type them in upper case or lower case or a combination of both, case is not important.
For example:
the arguments "-project, "-PROJ" and "-p" are
all interpreted to mean the -Project option.
The argument "-prj" will not be understood,
because consecutive optional characters were not supplied.
Options and other command line arguments may be mixed arbitrarily on the command line, after the function selectors.
The GNU long option names are understood.
Since all option names for
aegis
are long,
this means ignoring the extra leading '-'.
The "--option=value" convention is also understood.
The recommended alias for this command is
csh% alias aerbu 'aegis -rbu \!* -v'
sh$ aerbu(){aegis -rbu "$@" -v}
It is an error if the change is not in the being reviewed state. It is an error if the current user is not the reviewer of the change.
The aegis command will exit with a status of 1 on any error. The aegis command will only exit with a status of 0 if there are no errors.
See aegis(1) for a list of environment variables which may affect
this command.
See aepconf(5) for the project configuration file's
project_specific field for how to set environment variables for
all commands executed by Aegis.
change directory
complete development of a change
recall a change for further development
begin review of a change
add a reviewer to a project
fail review of a change
aeuconf(5)user configuration file format
aegis version 4.22 Copyright (C) 1991-2006 Peter Miller; All rights reserved.
The aegis program comes with ABSOLUTELY NO WARRANTY; for details use the 'aegis -VERSion License' command. This is free software and you are welcome to redistribute it under certain conditions; for details use the 'aegis -VERSion License' command.