flamesborderbgRFD.jpg

Nicoles Law

Home
2010 Firefighter Entrance Exam
Plain Street Fire
Firefighter Sunday 2009
2008 Year End Reports
Major Incidents
Old Major Incidents
Fire Alarm Broadcast
Announcements
Member News
Group Assignments
Stations and Apparatus
Pictures
Emergency Medical Services
Safety Tips
Cell Phones for Soldiers Info
Baby Safe Haven
CPR and First Aid Training
Nicoles Law
Circa 1960 Randolph Fire Pictures
A Historical Look Back
Contact Us
Links

Nicoles Law-  This law requires that all buildings which have fossil-fuel burning equipment or enclosed parking areas to have Carbon Monoxide detectors.  This will sense Carbon Monoxide which is a colorless, odorless tasteless gas.  This gas has been called the silent killer as persons are unaware they are being over come by this dangerous gas.  These detectors are required on every level of the home and within 10 feet of each sleeping area and in habitable portions of basements and attics.  The CO (Carbon Monoxide) Detectors maybe
   - Battery operated with battery monitoring ; Or
   - Plug-in's with battery back up; Or
   - Hard wired with battery back up ; Or
   - Low Voltage system; Or
   - wireless , or
   - Qualified combination (Smoke / Carbon monoxide alarm)
 
Acceptable combination smoke detectors and carbon monoxide alarms must have simulated voice and tone alarms that clearly distingusih between the two type of emergencies.  State building code mandates that only photoelectric combination alarms are permitted within 20 feet of a bathroom or kitchen.
 
All affected residences must install approved carbon monoxide alarms by MARCH 31st 2006   Where hard wired systems are required the dead line is January 1st 2007.
 
If you have any questions you can call the Fire Prevention division of the Randolph Fire Department at 781 961 0991 Ext 15  or  the Department of Fire Services web site at
 

 

Enter supporting content here